V 310

ICU Ventilator

Noccarc V310 offers an advanced, compact yet reliable ICU ventilation solution. Carefully crafted with the combination of cutting edge research and advanced manufacturing technologies, the turbine based design enables highly efficient independent operation and a wide range of ventilation modes, including High Flow Nasal Cannula. The IOT enabled system allows central data monitoring and logging remotely making Noccarc V310 an accessible easy to manage option for the health professionals in the current case of Covid-19 pandemic.

Features

High Flow Oxygen Therapy

Noccarc V310 HFNC mode when used with humidifier, is capable of delivering up to 100%.

10 inch Touchscreen with User-friendly Interface

The integrated 10 inch Touchscreen Interface provides great monitoring and controlling capabilities.

8 Hours Battery Backup

Noccarc V310 is a powerful turbine based ventilator with a battery backup of upto 8 hours.

Inbuilt Programmable Nebulizer Synced with Inspiratory Phase*

Inbuilt programmable nebulizer provides quick and convenient way to administer medication

IoT Enabled Central Data Monitoring and Logging**

Central monitoring system incorporates innovative features such as flexible trending and display capabilities

Volume Controlled Ventilation

VC-CM
VC-AC
VC-SIMV
PRVC-CMV
PRVC-AC
PRVC-SIMV


Pressure Controlled Ventilation

PC-CMV
PC-AC
PC-SIMV


Spontaneous Breathing Support

PS/CPAP (PSV) with Apnea Backup Ventilation
APRV
HFNC *


Therapy type

Invasive Ventilation

Non-invasive Ventilation (NIV)

O2 therapy


Types of Patients Supported

Adults and Paediatric


Apnea Backup Ventilation


Hign Flow Nasal Oxygen Therapy

*HFNC accessories are not included with the ventilator and have to be ordered separately

Respiratory Rate (RR)

1 – 60 BPM


Peak Inspiratory Pressure

50 cm of H2O


PEEP

0 – 50 cm of H2O


Pressure Support

0 – 50 cm of H2O


Inspiratory Time (Ti)

0.2 – 5 s


I:E Ratio

1:6 to 6:1


Tidal Volume (VT)

50 – 2000 mL


Inspiratory Flow Rate

280 L/min (Internally restricted to 160 L/min)


Trigger Flow Sensitivity

1 – 20 L/min


Volume Accuracy

2 – 3% of full scale between 10 L/min – 80 L/m


O2 concentration (FiO2)

21 – 100 %


FiO2 control

Closed loop electronic manipulation


Recruitment Tools

Inspiration Hold

Expiration Hold


Leak Detection and Compensation

Upto 200 ml


O2 Therapy

Continuous flow 0 – 80 L/min

Concentration 21 – 100 %


Nebulizer

for 5, 6, 7, 8, 9, 10 minutes

Synced with Inspiratory Phase *


Oxygen Input

45 – 60 PSIG


Screen

10” TFT LCD Touchscreen


Dimensions Patient Unit

395 X 340 X 255 mm


Weight

~ 10.1 Kg Patient Unit

~ 25 Kg with trolley


Battery

Lithium, Internal


Battery Back-up Time

Upto 8 hours


Mains Input

200 – 240V AC, 50 – 60Hz


Input Current

<2.00 A


Power Consumption

<150 W


 

 

Pressure Measurements

Peak Inspiratory Pressure (PIP)
Positive end Expiratory Pressure (PEEP)
Plateau Pressure ( Pplat )
Driving Pressure
Mean Pressure ( Pmean )
Range: 0 to 100 cm H2O


Flow Measurements

Expiratory minute Volume ( MVe )
Inspiratory minute Volume ( MVi)
Spontaneous Expired minute Volume ( Spont. MVe )
Range 0 to 160 L/min


Volume Measurements

Inspiratory Tidal Volume ( V Ti )
Expiratory Tidal Volume ( VTe )
Total Leak Volume

Download Brochure
Graphic Mode with Display
Alarms for Device and Patient

Alarms for Patient Safety

PEEP (High / Low)
Respiratory Rate (High / Low)
Tidal Volume (High / Low)
FiO2(High / Low)
High Inspiratory Pressure
Patient Disconnection
Battery Low


Alarm Features

Color coded alarms based on priority
Adjustable Apnea Alarm time ( Tapnea )
History of last 200 alarms